Physical systems your agents work inside.

The Foundry systems, each an environment with its tasks and its verifier, and the open physics library alongside them.

Ships today · Flagship task pack

Liquid-Cooled AI Compute Rack

204 Harbor tasks across commissioning, live fault forensics and compound degradation, graded by a separate verifier with no LLM judge.

Buy · $12,500Request invoiceFoundry preview

Built · By invoice

Spacecraft Bus

Keep an orbital AI-compute spacecraft running through a 72-hour communications blackout while managing power, thermal and pointing.

Talk to us

Built · By invoice

Robotic Lab Cell

Coordinate grasping, motion and precision liquid handling to commission a robotic wet-lab cell.

Talk to us

Have a physical system of your own? We build an environment around it, from $20,000. Start a custom environment.

Technical reference · open physics library

Case studies.

Every model in the open physics library runs at the open MCP address. Each case names who measured the original hardware, how close the model comes, and where it stops.

SPERT III, a nuclear test reactor

In the 1960s a reactor was given sudden surges of power, on purpose; seventy of them fill three tables of its 1969 report.

Read the case

The model follows the 70 tests of the 1969 report’s three tables: cold, hot at 260 and 500 °F, hot standby and full power. Fitted on all 70 and compared with each test left out of the fit in turn, it gives peak power within 6.8 percent at the median test, energy within 8.6 and time to the peak within 4.1. Its largest gap is the 3 tests from operating power: 81.2 percent low in energy. SPERT III: technical case

One square for each of the 70 tests. The three hollow ones are from operating power, the largest gap.

SPERT III with its C-core, through boiling

The same test reactor, loaded with a core of fuel plates, was given surges of power under pressure and flow: its 1964 report tabulates 126 surges, 111 of them used.

Read the case

The model carries the plates, the film of water beside them, boiling and void. Fitted on all 111 transients of the 1964 report and compared with each tenth left out of the fit in turn, it gives peak power within 10.4 percent RMS, energy to the peak within 17.2 and the hottest plate’s rise at its first maximum within 11.3. Its largest gap is high flow: at 5,000 to 20,000 gpm the plate maximum reads 24.6 percent RMS. The SPERT III C-core: technical case

One square for each of the 111 transients, each in a tenth left out of the fit in turn.

The Molten-Salt Reactor Experiment

At Oak Ridge in the 1960s a reactor ran on fuel dissolved in molten salt and pumped round a loop.

Read the case

When the pump runs, the salt carries delayed-neutron precursors out of the core, and the control rods make up the difference. Fitted on the start-up of the 1968 report, the model followed the 73 coast-down rod readings not in the fit within 6.5 pcm RMS, the largest 19.7. Its gap is the start-up after the rod’s peak: 53.9 pcm high at 17.1 seconds. The Molten-Salt Reactor Experiment: technical case

73 readings not in the fit, RMS6.5 pcm

The largest of them19.7 pcm

The rod reactivity through the coast-down. The two bars are to scale.

The TRIGA Mark II reactor in Ljubljana

At the Jožef Stefan Institute a research reactor is pulsed: a rod is shot out, and the power rises to hundreds of megawatts.

Read the case

Fitted on 36 of the 43 recorded pulses of the institute’s pulse database, the reactor’s model gives peak power on the 12 rows of core 231 not in the fit within 1.21 of the comparison’s uncertainty, 18.0 percent RMS. Its instrumented fuel element 6753, fitted on 39 pulses, gives the thermocouple’s maximum rise on all 16 pulses not in the fit within 9.2 percent. Its largest gap: peak power reads 44 and 23 percent low on the two rows of 22 March 2018. The TRIGA reactor in Ljubljana: technical case

Element 6753, all 16 pulses within9.2%

Its target10%

The thermocouple’s maximum rise, on the pulses not in the fit. The two bars are to scale.

NASA’s Stardust capsule

In 2006 a capsule carrying comet dust fell back to Earth.

Read the case

At the worst moment of the fall it weighed nearly 33 times its normal weight. With nothing fitted, from the capsule’s design alone, the model gives 32.17 g against the 32.89 g of NASA’s reconstruction: within 0.72 g. Its gap is heat flux, 696 W/cm² against NASA’s computed 762 to 1000. The Stardust capsule: technical case

The model32.17 g

NASA’s reconstruction32.89 g

The worst moment, twice. The two bars are to scale.

The James Webb Space Telescope

To take a picture, the telescope locks onto one star and holds it still.

Read the case

The model says where that star will sit 64 milliseconds from now. On 795,021 quiet frames not in its fit, its error is 0.79 and 0.81 of the error of assuming the star stays where it was last seen. Its gap is the frames inside a disturbance, where it does worse and flags them. The James Webb Space Telescope: technical case

The model’s error, one frame ahead0.79

Assuming the star stays put1

On one axis; 0.81 on the other. The two bars are to scale.

Great Britain’s power grid

When a major power link suddenly drops, the electricity of a whole country stumbles for about a minute.

Read the case

The model says how far the frequency falls and how it comes back. Fitted on all 86 trips and compared with each one left out of the fit in turn, the depth of the fall comes within 0.224 relative error and the frequency near 60 seconds within 0.076 Hz. Its largest gap is the newest trips: on the 11 since November 2025 its falls run 23 percent too deep on average. Great Britain’s power grid: technical case

One dot for each of the 86 trips, each left out of the fit in turn. The eleven hollow ones, since November 2025, are the largest gap.

Two satellites, LAGEOS-1 and LAGEOS-2

Two mirror-covered spheres circle the Earth and are tracked by laser.

Read the case

Told where each one was at a single moment, with nothing fitted, the model said where it would be a week and more than forty orbits later. After some three million kilometres it was within 32 metres on one and 22 on the other. Its gap grows with the length of a forecast, since it carries no drag. LAGEOS-1 and LAGEOS-2: technical case

LAGEOS-1, within32 metres

LAGEOS-2, within22 metres

After seven days. The two bars are to scale with each other.

A tyre on ice

How much grip does a tyre have on ice?

Read the case

Engineers at Virginia Tech measured it on their ice rig and published what they found. Fitted on 72 of their 252 runs, the model gives the friction ratio on the 60 test cells not in the fit within 0.034, where the usual fixed ratio of 0.1 is off by 0.122. Its gap is the test session: one session carries about ±0.03 on the ratio. A tyre on ice: technical case

One square for each test cell not in the fit.

The power source on NASA’s Curiosity rover

The nuclear battery on Curiosity fades a little every day.

Read the case

Fitted on its first 2,060 days, the model followed the 1,279 days from day 2,809 to the end of the record, outside the fit, within 0.94 W (RMS). Its gap is that it reads high and the gap grows: over the final 365 days the mean is +0.010094 of the generator’s 115.4 W, about 1.16 W, against a target of 0.010. Curiosity’s generator: technical case

Over 1,279 days, RMS0.94 W

The final 365 days, mean1.16 W

Each bar against a full width of 1.154 W, the target of 0.010 of 115.4 W.

Technical reference · open engine v0.15.3

The whole library, by domain.

Every model below is part of the Apache-2.0 open engine: query it at the open MCP endpoint, run the sample sets, or see the Foundry environments.

Each entry shows its MCP identifier (domain/card for time-stepping integrators or solver <id> for steady and boundary-value solvers), what physical system it computes, and an expandable fold carrying its verbatim out-of-sample validation accuracy and largest residual gap.

How each model is validated

compared with measurementheld to a reference calculationanalytical reference model

Power grids, batteries & thermal systems

  • Great Britain’s power grid, when an interconnector link tripsCompared with measurementenergy/grid_gbFrequency of the Great Britain synchronous area after an importing interconnector trips, from the half hour’s published inertia and the Dynamic Containment, Moderation and Regulation NESO held, on NESO’s curves: a fitted plant response, demand relief and an energy ledger every step.
    Validation & operating boundsCompared with all 86, each left out of the fit in turn: depth of the fall within 0.224 RMS relative error, steepest second 0.237, near 60 s 0.076 Hz, trace 0.035 Hz median. Gap: since November 2025, 11 trips, depth 0.359 RMS, 23 percent too deep on average, 106 percent on 21 March 2026 […]
  • Three Tesla Model 3 2170 cells, as one physical modelCompared with measurementenergy/cell_2170_model3Terminal voltage and core temperature of one Tesla Model 3 2170 lithium-ion cell, cell m80, m1000 or m448-N, as one physical model with memory from -20 to 40 degC, from a terminal current and a measured case temperature, a step of one second: Butler-Volmer charge transfer with Arrhenius kinetics read at the core, the salt’s transport limit, and the core warmed by the cell’s own heat.
    Validation & operating boundsCompared with each cell left out of the fit in turn, its 234 runs not in the fit: within 20.2 mV RMS […] Gap: the discharge at the rated current at -20 degC, 68.7 mV RMS on cells left out (49.6 fitted) […]
  • One Panasonic 18650PF lithium-ion cellCompared with measurementenergy/cell_18650pfTerminal voltage and state of charge of one Panasonic NCR18650PF lithium-ion cell, new, at 25 degC, in a held discharge at one current from a rested cell at any state of charge, with no temperature and no memory of the load before.
    Validation & operating boundsCompared with the eleven held 1C discharges from full charge not in the fit: terminal voltage within 27.8 to 30.0 mV RMS (target 50), largest single error 57 mV […] Gap: on one discharge at 0.87 A in 14 holds, not in the fit, 56.7 mV RMS (target 50), 204 and 206 mV in the last two holds, and it runs 71 s past the cell’s 2.5 V, delivering 0.60 percent more than the cell.
  • A lithium-ion cell in oven thermal runawayCompared with measurementenergy/runaway_18650_lcoThermal runaway of one LiCoO2 18650 cell in an oven, under a heater or in an adiabatic calorimeter: the four Hatchard-Kim stages, a separator melt at 130 degC and a vent at 160 degC, one heat capacity, oven loss and an energy ledger.
    Validation & operating boundsCompared with each record left out of the fit in turn, the constants refitted on the other 12: onsets within 16.2 K RMS on 10 records (9.8 on the eight reprinted cells), peaks within 51.7 K RMS on 7, Hatchard’s 155 degC oven running away at 64.8 min against 51.1 […] Gap: at 150 degC the card runs away at 109.7 min where Hatchard’s cell did not in 120 […]
  • The MMRTG radioisotope power source on NASA’s Curiosity roverCompared with measurementenergy/generator_mmrtg_f1Daily-average electrical output of one radioisotope generator, flight unit F1 on the Curiosity rover, from landing on, with no load: electrical power, thermal power and converter fading, with the energy ledger closed at every step.
    Validation & operating boundsCompared with the 1,279 days 2,809 to 4,087, outside the fit and the choice of structure: within 0.008129 of 115.4 W RMS (about 0.94 W; target 0.010), worst day +0.02251 (2.60 W high, day 3,546). Gap: it reads high and the gap grows, +0.0031, +0.0045 and +0.0096 of 115.4 W over three successive years and +0.0107 over the last 184 days […]
  • Curiosity’s MMRTG power source, Seebeck formCompared with measurementenergy/generator_mmrtg_seebeckDaily-average electrical output of the radioisotope generator on the Curiosity rover, flight unit F1, in the Seebeck matched-load form, the second form of this generator beside generator_mmrtg_f1: electrical power, thermal power and energy from landing on, with no load, the fuel’s decay entering twice.
    Validation & operating boundsCompared with all 4,088 days, all in the fit: within 0.00319 of 115.4 W RMS across all 4,088, about 0.37 W […] Gap: its largest error on one day is +0.0160 of 115.4 W, 1.85 W, on mission day 3,546 […]
  • A bladder hydraulic accumulator on a test rigCompared with measurementenergy/accumulator_sbo450Gas pressure, temperature and energy ledger of the nitrogen in one HYDAC SBO450-0.6 diaphragm accumulator on the TU Darmstadt rig, as a piston moves oil in and out: Peng-Robinson nitrogen, one time constant of heat exchange with the wall.
    Validation & operating boundsCompared with the 285 runs not in the fit, 40 to 120 bar load and half the charge, 0.01 to 20 Hz: pressure swing per piston travel within 0.93 percent median (target 2.0), lead within 0.27 degrees median (target 0.5) […] Gap: 2.72 percent median at 109 to 132 bar (target 2.0) […]

Reactors & fusion

  • SPERT III nuclear test reactor: all 70 transients of IDO-17281Compared with measurementenergy/reactor_spert3Reactivity-insertion transient of the SPERT III E-core test reactor, 1392 UO2 rods, from cold startup, hot startup at 260 and 500 degF, hot standby or operating power, by six-group point kinetics with the transient rod’s worth over its travel, radial conduction in six rings of the average, the clad thermocouple’s and the peak rod, Doppler and moderator feedback and convection to the water: power, energy released, the fuel, clad and water temperatures and the hot-spot clad temperature, with the neutron and heat ledgers closed at every step.
    Validation & operating boundsCompared with each of the 70 tests left out of the fit in turn, refitted on the other 69 from a start that never saw it: at the median test peak power within 6.8 percent, energy to the peak within 8.6, time to the peak within 4.1 and hot-spot clad rise within 9.2 […] Gap: from operating power, 19 MW, the 3 tests read 11.5 percent low in peak power, 81.2 low in energy and 39.0 early at the median, the reactivity going in over 0.10 to 0.16 s in Figs. D-68 to D-70 against the rod’s 0.06 to 0.08 s […]
  • SPERT III with its C-core, through subcooled boilingCompared with measurementenergy/reactor_spert3_ccorePower burst of the SPERT III C-core test reactor with subcooled boiling and void: point kinetics with six delayed groups and three nodes of plate meat, cladding, film, bulk water and vapour, the plates’ feedback lagging their temperature by 5.69 ms and the film thinning with the flow: power, energy released and the hot-spot plate temperature through its first maximum.
    Validation & operating boundsCompared with each tenth of the 111 left out of the fit in turn: peak power within 10.4 percent RMS, energy to the peak 17.2, the hot-spot plate rise at peak power 12.3 and at its first maximum 11.3 […] Gap: left out, at 5000 to 20,000 gpm the plate maximum reads 24.6 percent RMS (12.9 without transient 03618), against a repeat scatter of 5.5 […]
  • Oak Ridge Molten-Salt Reactor Experiment, fuel pump start and coast-downCompared with measurementenergy/reactor_msre_pumpReactivity the control rods of the Molten-Salt Reactor Experiment supply above their static critical position at zero power while the fuel pump starts or coasts down: six delayed-neutron groups carried round the 25.2 s loop in 252 parcels of salt, born and weighted by one axial sine of flux and importance, the fuel flow lagging the pump, rod 1 no faster than its drive, and a per-group ledger closed at every step.
    Validation & operating boundsCompared with the 73 coast-down rod readings of Fig. 24, not in the fit: within 6.5 pcm RMS, mean +2.3, largest 19.7 […] Gap: after the rod’s peak the card’s precursor wave round the loop runs large, 53.9 pcm high at 17.1 s […]
  • Jožef Stefan Institute TRIGA Mark II reactor, pulsedCompared with measurementenergy/reactor_triga_jsiPulses of the TRIGA Mark II reactor of the Jozef Stefan Institute, Ljubljana (56-element core of standard U-ZrH fuel, rod tables of cores 215, 217 and 231), by point kinetics with six delayed groups and fuel-temperature feedback: power, energy released and core-average fuel temperature through the pulse, the scram and after it.
    Validation & operating boundsCompared with the 20 table rows of the same cores not in the fit, other days on the fitted tables, in units of the comparison’s uncertainty: on 12 rows of core 231 from 22 and 28 March 2018, peak power within 1.21 RMS (target 1.5; 18.0 percent), energy within 50 ms of the peak within 1.47 (15.7 percent) and thermocouple maximum within 1.29 (8.0 K) […] Gap: peak power reads 44 and 23 percent low on the two rows of 22 March 2018, a day whose printed 1.5 and 2.0 dollars stand at rod positions the fitted day prints as 1.75 and 2.25 (worst 3.02, target 3) […]
  • Instrumented TRIGA fuel element 6753, through a pulseCompared with measurementsolver fuel_rod_triga_jsiTemperature of the instrumented fuel element 6753 of the JSI TRIGA Mark II reactor through a pulse, from the core’s energy release given as a history: radial conduction through the zirconium rod, the U-ZrH1.6 meat, a gas gap and the SS-304 clad by backward Euler in the enthalpy, 1.387/56 of the core’s energy into the meat, convection and boiling to the pool, and the fuel thermocouple as a first-order lag, every step’s energy account closed to 1e-9.
    Validation & operating boundsCompared with 16 pulses of cores 217 and 231 at 2.0 to 2.6 printed dollars not in the fit, from each record’s own power: the thermocouple’s maximum rise within 9.2 percent on all 16 (9.2 low to 0.3 high, mean 5.5; target 10), its time after the power peak within 19.6 percent (mean 11.9; target 20), and the rise 10 s after the peak within 4.3 percent on the 8 records that run that long (mean 3.1; target 10). Gap: on all 55 pulses the maximum rise reads 6.3 percent low on the 2014 core 215 and 7.7 on the 2015 core 217 at the mean, 2.2 on the 2018 core 231 […]
  • The JET tokamak, DTE1 pulses of 1996 to 1997Compared with measurementenergy/tokamak_jet_dte1Heated pulse of JET in its 1996 to 1997 D-T campaign, ELMy or hot-ion H-mode: thermal energy, D and T beam ions slowed classically on the measured electron temperature, the ICRH tail and alphas, the central ion temperature, and the thermal and beam-target D-T fusion power, the energy ledger closed every step.
    Validation & operating boundsCompared with 10 pulses, each left out in turn, medians: thermal energy within 16.0 percent of peak RMS, fast ions 5.3, fusion power 16.4 (7 D-T) […] Gap: 42976 left out, hot-ion fusion energy 0.392 (4.03 MJ against 10.30).
  • The MAST tokamak, vertical displacement eventCompared with measurementenergy/tokamak_vde_mastVertical displacement event of the MAST spherical tokamak’s plasma in shot 15045, from 0.250 s: a rigid plasma carrying EFIT’s 755 kA in MAST’s held coil field, against the eddy currents of its 126 passive elements as one wall circuit and the P6 vertical-control pair driven by the amplifier’s voltage, from any start inside the vessel until its boundary reaches the wall: height, velocity, the two currents and the vertical force on the vessel, with the energy ledger closed at every substep.
    Validation & operating boundsCompared with the measured event of shot 15045: P6U current at the end of the linear phase within 6.2 percent of the shot’s (-2,933 ampere-turns against -3,126; target 25) […] Gap: the growth rate is 93.2 percent low (6.55 per second against 96.3; 94.1 percent low on the probe signal): in the shot P6 held its flux, and a rigid plasma held so needs 2.04 times the rigid shift’s stiffness to grow at 96.3.
  • Deuterium-tritium beam-target fusion across TFTR and JETHeld to a reference calculationsolver tokamak_dt_beam_targetThe deuterium-tritium fusion rate of one time slice of a tokamak pulse in steady state, from its analysed profiles (temperatures, densities, fuel mix in up to 128 radial shells) and its neutral beams: thermal, beam-target from classical slowing-down with the Bosch-Hale cross-section, and beam-beam reactions, the fusion power and the neutron rate.
    Validation & operating boundsHeld to TRANSP’s fusion power in the International Multi-Tokamak Confinement Profile Database on 34 TFTR slices outside any fit. As served, with its three limits: 27 answered and 7 refused by name (5 FastIonShareTooLarge, 2 BeamChangeTooRecent) […] Gap: the solver’s fast ions are 1.1 to 3.1 times the database’s in the shell of largest excess, so the median agreement is partly a cancellation of that missing drag.
  • Boron-seeded hydrogen plasma in the Large Helical DeviceCompared with measurementsolver fusion_pb11_lhdProton-boron-11 fusion of one hydrogen neutral beam in the boron-seeded hydrogen plasma of the Large Helical Device, the beam protons slowed on electrons, protons and boron in twenty radial shells: alpha particles per second, fusion power, the share of beam protons that fuse, the alpha emissivity profile, and the fast protons over the electrons.
    Validation & operating boundsCompared with measured alpha count rates under negative-ion beams of 127.45 to 160.25 keV and a 45 keV beam, each shape after one common scale factor (target: every point within a factor of 2): the six beam-energy points in the measured order (Spearman 0.943), worst factor 2.94 […] Gap: from 128 to 160 kV it rises 11.1 times where the measurement rises 2.10, below the 4.4 that a cross-section with no resonance at all gives […]
  • Uniform thermal proton-boron fusion plasmaHeld to a reference calculationsolver fusion_pb11_thermalEnergy balance of a uniform thermal proton-boron-11 plasma: the electron temperature at which the electrons balance, fusion, bremsstrahlung, synchrotron and exchange power, and the ignition margin.
    Validation & operating boundsHeld to the published calculations of Ochs et al. 2022 and Putvinski et al. 2019: the electron temperature at 300 keV and 13 percent boron within 2.3 percent (target 5), the largest fusion power over bremsstrahlung within 0.2 percent (target 2). The comparison’s request at 300 keV (13 percent boron, electron density 1.52e20 m^-3, 20 T, wall reflectivity 1, kinetic enhancement on) gives an electron temperature of 159.33 keV against a published 163.0, and an ignition margin of 0.037. The worked example, example_solve, is another plasma at 300 keV (15 percent boron, 1.6e20 m^-3, 6.661 T, wall reflectivity 0.95, kinetic enhancement off): an electron temperature of 113.152 keV and an ignition margin of -1.042, so it does not ignite. Gap: synchrotron over fusion power is 7.9 percent off a plain-Python model of the same balance (target 5), and two published bremsstrahlung fits differ by as much as the ignition margin.
  • Inertial-confinement fusion burning hot spotCompared with measurementsolver icf_hotspot_burnBurn of a stagnated deuterium-tritium hot spot of inertial confinement fusion, from the mirror image of the ideal implosion through peak compression and ignition to disassembly: a 0-D hot spot (one temperature, Bosch-Hale burn, Krokhin-Rozanov alpha deposition, Betti’s conduction ablation, bremsstrahlung with free-free absorption) inside a 64-zone Lagrangian shell of cold fuel, with an energy, particle and mass ledger at every step: yield, burn-up, burn width, the neutron-averaged hot spot, the energy accounts and the field’s ignition measures.
    Validation & operating boundsCompared with the seven shots as published (targets: yield within a factor of 2, burn width within 30 percent, burn-up within a factor of 2, yield amplification within a factor of 1.5): 3 of 24 targets reached and no shot within all of its own […] Gap: no reading reproduces both the yield and the burn width of the ignition shots […]

Orbital, space & atmospheric entry

  • NASA’s Stardust sample-return capsule, Earth entryCompared with measurementaerospace/capsule_stardustEntry of the Stardust sample return capsule on 15 January 2006, as a point mass with tabulated drag, no lift, no wind and a yearly standard atmosphere: altitude, speed through the air, Mach number, load, heat flux, and at the nose the stagnation pressure, recovery enthalpy and heat-transfer coefficient a heat shield takes, from entry interface to the drogue-deployment condition the radar recorded.
    Validation & operating boundsCompared with NASA’s reconstruction of the entry and the radar record of parachute opening: peak load 32.17 g against 32.89 g, within 0.72 g (target 3.64 g) […] Gap: heat flux 696 W/cm2 against NASA’s computed 762 to 1000 […]
  • NASA’s InSight capsule, Mars atmospheric entryCompared with measurementaerospace/capsule_insightEntry of NASA’s InSight capsule at Mars on 26 November 2018, as a point mass with the 2008 Phoenix drag database, no wind, and the lift over drag as the load: altitude, speed through the air, Mach number, dynamic pressure and load, from the top of the atmosphere to the flown parachute deployment.
    Validation & operating boundsCompared with the last 59 s before the parachute, not in the fit: speed within 7.2 m/s RMS, radius within 245 m and deceleration within 0.031 g over the 58 whole seconds […] Gap: with no lift the run reaches the flight’s radius at the parachute 22.8 s late and is 4.24 km high there (targets 15.1 s and 3.5 km) […]
  • Re-entry plasma sheath around NASA’s RAM C-II probeCompared with measurementsolver plasma_sheath_ram_c2The plasma sheath around NASA’s RAM C-II re-entry probe (a 15.24 cm hemisphere on a 9 degree cone) at one flight point: the equilibrium normal shock and stagnation point of 11-species air, the gas carried along the body to the nose station (x/D 0.15) and the cone station (x/D 0.76) with Dunn and Kang’s 26 reactions at finite rate, the electron density, the plasma frequency, and whether a radio signal of the asked frequency is blacked out at each.
    Validation & operating boundsCompared with the reflectometer onsets of NASA TN D-6062 Table X at 7.65 km/s: electron density 0.94 of the measured, within a factor of 1.07, at the cone station’s X band at 70.0 km […] Gap: above 73.6 km, where the shock is as thick as the layer and electrons are lost to the cold wall, the density reads about 3 times high (3.28 at 77.7 km, 2.92 at 80.0 km).
  • Charring phenolic heat-shield ablator slabCompared with measurementsolver ablator_slabA flat slab of charring heat-shield material heated on one face: wear, face temperature, depth of charring and the heat and mass accounts, for a PICA model built from the open record or the test material TACOT 3.0.
    Validation & operating boundsCompared with 31 arc-jet tests outside the fit: wear within its target on 28 of 31 (target 25), mean −5.3 percent over all 31 (−2.6 over the 30 without the pure-nitrogen test; target within 8) […] Gap: the face runs 4.1 percent hot on average (target 3.5), and Stardust nose wear is a third high.
  • Laser-ranged geodetic satellites LAGEOS-1 and LAGEOS-2Compared with measurementaerospace/satellite_lageos1Free flight of the laser-ranging satellite LAGEOS-1 from a published position and velocity, in a frame turning with the Earth: the Earth’s field to degree and order 12, the Sun and the Moon, the solid tide, sunlight pressure and relativity, with the energy and the angular momentum about the Earth’s axis held at every step.
    Validation & operating boundsCompared with the 42 runs of the six weeks outside that choice, two of LAGEOS-1 and four of LAGEOS-2: LAGEOS-1 within 0.65 m of the published orbit after one revolution (target 1 m), 3.8 m after one day (10 m) and 32 m after seven days (100 m) […] Gap: the error grows with the length of a forecast, from 0.65 m after one revolution to 32 m after seven days on LAGEOS-1, as the card carries no drag, no light reflected from the Earth and no ocean tide.
  • Solar System n-body ephemeris, carried forward 21 yearsCompared with measurementaerospace/solar_systemThe Solar System as thirteen point masses in free motion: the Sun, Mercury, Venus, the Earth, the Moon, the barycentres of the Mars, Jupiter, Saturn, Uranus and Neptune systems, and Ceres, Pallas and Vesta, under Newton’s and the relativistic forces between every pair and the Earth’s oblateness on the Moon. The caller supplies every position and velocity.
    Validation & operating boundsCompared with 10,134 ranges of three spacecraft in four files, not used to choose it, in one run of 7,670 days: Mars Odyssey to 2006 within 695 m (target 700 m), 270 m RMS […] Gap: in mid-2007, 44 Odyssey ranges and 34 Mars Reconnaissance Orbiter ranges are outside their targets, by at most 8 and 10 percent, from the 340 asteroids the card leaves out […]
  • James Webb Space Telescope fine-guidance line of sightCompared with measurementaerospace/los_jwst_fine_guideThe line of sight of the James Webb Space Telescope in quiet fine guide, read by its Fine Guidance Sensor every 64 ms: a Kalman filter through one fine-guide file’s flight centroids, giving on both axes the next centroid and its stated variance.
    Validation & operating boundsCompared with the 795,021 quiet frames of 134 files not in the fit: error one frame ahead 0.510 mas on x and 0.472 on y RMS, within 0.790 and 0.807 of the last centroid’s (target 0.85) […] Gap: inside disturbances it is worse than the last centroid, 2.03 against 1.00 mas on x and 1.57 against 0.78 on y, its stated variance 12 to 17 times too small […]
  • Webb angular momentum build-up under solar radiation pressureCompared with measurementaerospace/momentum_jwst_srpTotal angular momentum of the James Webb Space Telescope at Sun-Earth L2, held by its reaction wheels between momentum unloads under sunlight pressure on its sunshield, from its attitude quaternion and the Sun’s direction and distance: one sunlit layer of 220 m² with JWST’s published optical numbers.
    Validation & operating boundsCompared with the three months after the fit: the daily growth of |H| within 0.1 of the observed plus 0.2 N m s on 23 of 28, 15 of 28 and 17 of 30 days (target 80 percent) […] Gap: the daily change of the vector H is within that allowance on 14 of 28, 8 of 28 and 8 of 30 days (target 80 percent): beyond 2 degrees of roll its torque about the boresight is off by about 30 µN m […]
  • Webb angular momentum by sunshield dihedral geometryCompared with measurementaerospace/momentum_jwst_dihedralTotal angular momentum of the James Webb Space Telescope at Sun-Earth L2, held by its reaction wheels between momentum unloads under sunlight pressure on its sunshield, from its attitude quaternion and the Sun’s direction and distance: the first layer as two plane slopes of 110 m² meeting along a ridge on the boresight, each falling 4.03 degrees towards the Sun, so that the Sun’s roll turns into torque about the boresight.
    Validation & operating boundsCompared with the two months after the fit: the daily growth of |H| within 0.1 of the observed plus 0.2 N m s on 25 of 28 and 22 of 30 days (target 80 percent) […] Gap: the daily change of the vector H is within that allowance on 18 of 28 and 13 of 30 days (target 80 percent), 0.42 N m s RMS against momentum_jwst_srp’s 0.81 […]
  • Asteroid Ryugu artificial impact crater (Hayabusa2 SCI)Compared with measurementaerospace/crater_ryugu_sciGrowth of the crater made on asteroid Ryugu by the 2 kg copper impactor of Hayabusa2 on 5 April 2019, by the law of crater size for dry sand held by gravity, with a laboratory clock: the radius at the level of the undisturbed surface from 0.1622 m until it stops, with no load.
    Validation & operating boundsCompared with the measured crater on Ryugu, not in the fit, with the law fitted on all thirteen laboratory craters: final radius 8.571 m against the apparent radius of 7.25 m, within 1.32 m, 18.2 percent (allowance 0.97 m) […] Gap: on Ryugu the card stops 1.32 m, 18.2 percent, above the measured apparent radius, outside the allowance of 0.97 m […]

Fluids, cryogenics & propulsion

  • Liquid-nitrogen cryogenic line water hammer (DLR FTTF)Compared with measurementsolver ln2_line_dlr_fttfFluid hammer in the liquid-nitrogen line of DLR’s Fluid Transient Test Facility, Lampoldshausen (9.29 m of 1.4541 tube, 19 x 1.5 mm, in a vacuum jacket), when its fast valve closes on a steady flow: pressure at the stations S1, S2 and S3, with the liquid’s stiffening under pressure, Churchill’s friction, the valve’s measured stroke and vapour cavities, the energy and mass ledgers closed at every step.
    Validation & operating boundsCompared with the 6 tests not in the fit on eleven error measures: in all six, the first rise at S2 within 1.7 percent, the front’s speed from S1 to S2 within 0.7 percent, the second surge’s time within 8.1 percent and the steady drop from S3 to S1 within 9.3 percent […] Gap: the plateau at S1 is 4.2 to 7.4 percent short, the first rise at S3 2.6 to 14.9 percent low, the second surge 6.9 to 22.6 percent high (39 and 111 percent at the two lowest pressures), and the late ringing after cavitation 10.0 to 13.1 percent short in period with a decay rate 78 to 91 percent under the measured.
  • High-Reynolds turbulent pipe flow in the Princeton SuperpipeCompared with measurementsolver pipe_flow_superpipeFully developed turbulent air flow in the smooth 129.36 mm bore of the Princeton Superpipe, by a mixing length with van Driest damping (kappa 0.41, A+ 26): Darcy friction factor, centreline-to-bulk velocity ratio and the mean velocity profile.
    Validation & operating boundsCompared with 19 friction factors and 21 profiles not used to choose it (McKeon 2004, NSTAP 2012 and 2013): friction factor within 1.38 percent RMS, worst 2.69 (the Prandtl-Karman law 2.17 RMS) […] Gap: the centreline ratio reads low on 20 of 21 profiles by 0.75 to 1.79 percent, and 2.99 percent low on the NSTAP profile at 81,330 […]
  • Backward-facing step separated flow (Armaly benchmark)Compared with measurementsolver step_flow_armalySteady laminar air flow over the backward-facing step of the Armaly rig (step 4.9 mm, channel 5.2 mm opening to 10.1 mm, expansion ratio 1.94), by the two-dimensional Navier-Stokes equations: the reattachment length and the velocity profile at one station.
    Validation & operating boundsCompared with 174 digitised circles at Reynolds number 389, none read when the solver was built: velocity profile within 0.0437 of the largest inlet speed RMS (target 0.05), worst station 0.052 (target 0.08) […] Gap: the reattachment length reads 6 to 7 percent short of Armaly’s plot at 389 (8.07 against about 8.6 step heights) and 5.8 percent short at 97, agreeing within 1 percent near Reynolds number 300 […]
  • APC 10x7E electric propeller performanceCompared with measurementsolver propeller_apc_10x7eThrust and shaft power of the APC Thin Electric 10x7 propeller (two blades, 10 inch) at one rotational speed, airspeed and air density, by blade-element momentum theory on the chord and blade angle measured at 18 stations of this propeller, with one blade section and Prandtl’s tip loss.
    Validation & operating boundsCompared with the 64 points of the 4 sweeps at 6015 to 6531 rev/min, not in the fit: within 4.85 percent of full scale on average (target 4.0), worst 10.16 (target 10.0) […] Gap: the answer reads low at every point outside the fit, by 5.0 percent of full scale in thrust coefficient and 4.7 in power coefficient on average, because the measured coefficients rise with speed and the model’s do not […]
  • Hydrodynamic oil-flooded journal bearingCompared with measurementsolver journal_bearing_sheffieldOil film of the University of Sheffield journal bearing test platform at 65 °C, by the Reynolds equation for a rigid aligned shaft and bush under a steady load and speed: Sommerfeld number, eccentricity ratio, attitude angle, minimum film thickness and peak film pressure.
    Validation & operating boundsCompared with the 16 runs not in the fit (every third run, inside the same loads and speeds): minimum film thickness within 0.058 mean absolute relative residual, worst 0.156, mean +0.020. Gap: on the 34 fitted runs, each left out of the fit in turn, the worst run is 0.324 off (mean absolute 0.062) […]
  • Spherical and surface TNT blast wave in airCompared with measurementsolver blast_wave_tnt_airThe incident blast wave of a charge of cast TNT in still sea-level air, a sphere in free air or a hemisphere on the ground: arrival time, peak overpressure, positive-phase duration and impulse, the Friedlander form, the pressure history and the fireball’s reach, from a sphere of detonation products under TNT’s JWL equation of state carried with the air by the spherical Euler equations to Sachs distance 4 and by weak-shock theory beyond, the energy of products and air held at every step.
    Validation & operating boundsCompared with the surface-burst positive-phase table, kept out of the fit (17 Z from 1.1 to 14.94): the impulse within 3.9 percent and the duration within 8.0 from Z 1.75 out […] Gap: near the fireball the positive phase is long, at Z 1.31 the impulse 25 percent and the duration 22 percent above Dewey’s free-air table (19 and 42 on the ground), and against Kingery-Bulmash the surface impulse reads 15 to 27 percent low, where its own stand 14 to 63 percent above Dewey’s.
  • Low-density argon virial and transport propertiesCompared with measurementsolver argon_pair_gasArgon gas at low density from one Lennard-Jones 12-6 pair potential: second virial coefficient, speed of sound at the asked pressure, and viscosity at zero density.
    Validation & operating boundsCompared with the 24 speeds of sound not in the fit (310 to 349.868 K): within 0.0074 m/s RMS (worst 0.0146), 0.023 of the ideal gas’s error […] Gap: the viscosity reads high at all 49 points, 2.95 percent at 291 K falling to 0.28 percent at 682 K, 1.4 to 20 times the measurement’s uncertainty.

Materials, structures, contact & signals

  • CMSX-6 single-crystal nickel superalloy creep at 980 °CCompared with measurementmaterials/creep_cmsx6Creep of one cast of the single-crystal nickel superalloy CMSX-6, loaded along [001] at 980 degC under a held load: the percentage creep extension of a 6 mm round test piece against the time since full load.
    Validation & operating boundsCompared with the 6 tests not in the fit: time to each level from 0.1 to 5 percent within 0.093 RMS in log time (about 9 percent), worst 0.240, over 33 times […] Gap: below 0.1 percent it starts late, 1.5 to 4 times the hours to 0.05 percent […]
  • Structural steel S355 dynamic and tensile modulus (BAM)Compared with measurementsolver modulus_bam_s355Young’s modulus and shear modulus of one of four test bars of S355J2+N structural steel, about 100 x 9 x 3 mm, cut from one hot-rolled sheet and rung at 24 °C at BAM Berlin, worked back from the bar’s measured flatwise and torsion resonant frequencies by a Timoshenko beam and Saint-Venant torsion, with the edgewise frequency they predict.
    Validation & operating boundsCompared with bars ERY1 and ERY2, across the rolling direction, not used to choose the model: Young’s modulus 215.68 GPa against 210.25 GPa from the tensile slope, 2.58 percent apart (target 2.49) […] Gap: against the tensile slope Young’s modulus reads 2.58 percent high across the rolling direction and 7.4 percent high along it (211.6 against 197.0 GPa), where the slope itself moves by up to 8 percent within one tensile test […]
  • Notched S235 steel plate pulled into elastoplastic yieldCompared with measurementsolver stress_plate_hole_s235The in-plane stress and displacement field of an S235 steel tensile bar with a 4 mm hole, the specimen of the Clausthal digital image correlation record (parallel length 20.05 by 3.05 mm, d/W 0.399), pulled on its gross section: plane stress with von Mises yield at 235 MPa, settled on finite-element meshes of rising refinement, stress concentration 2.249 on the net section.
    Validation & operating boundsCompared with the 1,186 points 4.5 to 12 mm from the hole, not in the fit: displacement within 0.675 um RMS in u_x (target 2.0) and 0.444 um in u_y (target 1.5), 0.571 um pooled against 1.015 for Kirsch’s infinite plate […] Gap: the solver yields a zone 1.53 mm deep at the hole, absent from the measured strain, so the strain 1.5 mm from the edge reads 26.0 percent high […]
  • Notched S235 steel plate within its elastic rangeCompared with measurementsolver stress_plate_hole_s235_elasticThe in-plane stress and displacement field of the same S235 tensile bar with a 4 mm hole as stress_plate_hole_s235 (parallel length 20.05 by 3.05 mm, d/W 0.399), with the steel not yielding: plane stress and Hooke’s law, settled on the same finite-element meshes, stress concentration 2.249 on the net section.
    Validation & operating boundsCompared with the same 1,186 points 4.5 to 12 mm from the hole: displacement within 0.638 um RMS in u_x (target 2.0) and 0.486 um in u_y (target 1.5), 0.567 um pooled against 1.015 for Kirsch’s infinite plate […] Gap: the record gives no yield strength of this sheet, and the elastic stress at the hole’s edge, 397.6 MPa at 106.26 MPa, has no measurement, the ring read starting 0.5 mm from the edge […]
  • Clamped aluminium cantilever ring-down (ETH benchmark)Compared with measurementsignal/cantilever_ethFree ring-down of one aluminium strip clamped at one end at ETH Zürich, in room air, in its first bending mode, with a fitted softening spring and fitted damping: the deflection and speed at the laser-1 station, 268 mm from the clamp, with no load.
    Validation & operating boundsCompared with 12 s to 24 s of a second ring-down of the same strip in the same clamp, test1b, not in the fit, in eleven blocks of eight periods: frequency within 0.0031 Hz (target 0.010), timing within 0.021 of a period (target 0.20), amplitude within 7.03 percent (target 5.0). Gap: the swing reads high in every block, 3.6 percent at 13 s growing to 11.7 percent at 23 s: the ring-down dies away too slowly once the swing is small.
  • Passenger tyre traction on ice (Virginia Tech rig)Compared with measurementmaterials/tire_eve_r19_iceLongitudinal force of one 235/55 R19 all-season tyre of the European project EVE on the prepared ice of the Terramechanics Rig at Virginia Tech, at a creep of about 0.06 m/s and a held slip, driven and retarded: the force as a friction ratio of the normal load, with the wheel work, the drawbar work and the slip heat.
    Validation & operating boundsCompared with the 60 cells, three repeats each, of the runs not in the fit, at 6.5 kN and at 2.5 bar: friction ratio within 0.034 RMS (target 0.045), 0.029 at 6.5 kN and 0.040 at 2.5 bar […] Gap: the error sits between test sessions, not repeats: the 18 condition means run 0.185 to 0.287, 0.029 apart in standard deviation against 0.005 to 0.011 between repeats, so a session carries about ±0.03 on the ratio […]
  • 32.4 GHz terrestrial microwave link rain attenuationCompared with measurementsignal/link_gothenburg_10010Path loss of one 32.445 GHz microwave link across 1.26 km of Gothenburg in rain, OpenMRG link 10010 sublink 587, from the rain rate at the gauge beside it: Recommendation ITU-R P.838-3 with nothing fitted for the rain, and an account of the water on the antennas.
    Validation & operating boundsCompared with the nine August rain events, 773 five-minute blocks not in the fit: within 0.581 dB RMS (target 0.90), 0.585 of the error of P.838 alone (target 0.80), summed attenuation 1.069 of the measured (0.75 to 1.25). Gap: the card’s five-minute peak is below the measured peak in seven of the nine events, by up to 2.2 dB, and the other direction of the link, sublink 588, reads 0.794 dB, a summed attenuation 2.30 of the measured.
  • Oceanographic hydrographic column acoustic depthCompared with measurementsolver seawater_columnDepth, density and sound speed at every level of one measured seawater cast (pressure, temperature, salinity), from the TEOS-10 Gibbs function and the weight of the water above, and the depth an echo sounder reads over it.
    Validation & operating boundsCompared with the ship’s echo sounder at 632 stations of 5 legs, none used to set the comparison: depth within a median of +4.59 m (target 10), 0.804 of stations within 20 m (target 0.80), each leg’s median +4.30 to +4.92 m (target 15). Gap: the solver’s depth reads deeper than the sounder’s, about +3 m on flat sea floor and +4.6 m pooled, and the fraction within 20 m is two stations over its target, 0.789 to 0.798 with leg 9, 10 or 13 left out.
  • 4 K Nb/a-Si/Nb Josephson junction (NIST)Compared with measurementsolver junction_nist_b7_s2Current-voltage characteristic of the NIST niobium / amorphous-silicon / niobium Josephson junction D220831b-B7_S2_1.5 at 4 K, the shunted junction with its capacitance and its own measured dissipative curve stepped in time: the mean voltage point by point from rest or from the voltage state, and its Shapiro steps under a microwave drive below the gap frequency, 691.6 GHz.
    Validation & operating boundsCompared with the zero-field curve outside the fit, 100 points rising and 100 falling, 0 to 0.91847 mA: voltage within 11.84 percent of I_c R_n RMS over the 175 points on the same branch (rising 7.10, falling 15.13, worst -36.3 at 0.1113 mA falling) […] Gap: the measured plateau is flat at 2.8498 to 2.8651 mV from 0.33 to 0.57 mA and the solver’s rises from 2.826 to 3.096 mV, up to 19.5 percent high […]
  • Kohn-Sham local-density atomic structure, H to ArHeld to a reference calculationsolver atom_dftSpin-unpolarized, non-relativistic local-density ground state of one spherical neutral atom: total energy, its four parts, and each orbital eigenvalue.
    Validation & operating boundsHeld to the NIST spin-unpolarized local-density tables within 1e-5 hartree, on the total energy, its four parts and every orbital eigenvalue of every atom. Gap: it is the local-density ground state, which carries the approximation’s own difference from the measured energy of the atom […]
  • Torsional contact mechanics on flat glassCompared with measurementmaterials/fingerpad_p02_glassOne human finger pad, the right index finger of participant P02 of the torsion experiment at UCLouvain, pressed on flat glass and twisted about the normal until it slips, as a bed of springs under a parabolic friction limit: the torque, the stuck fraction of the contact, the work and the heat.
    Validation & operating boundsCompared with P02’s 30 trials not in the fit, at 1 N, 10 N and 100 degrees a second: slip torque within 9.4, 29.3 and 13.0 percent of the mean of ten trials (target 5.62) […] Gap: the slip torque reads +9.4, +29.3 and -13.0 percent at 1 N, 10 N and 100 degrees a second, and +13.6 and +21.7 percent on the fitted trials at 0.5 and 5 N, against a target of 5.62 […]
  • Precision pinch-grasp slip and lift dynamicsCompared with measurementmaterials/grasp_lift_glass_4tuLift of a glass-faced object from a table between two finger pads: an instrumented test object, 0.2 kg with two vertical glass faces 60 mm tall, gripped at their middle by two pads with the friction and stiffness of the 4TU set’s human index finger pads on glass, each a Cattaneo-Mindlin contact that sticks, slips at its edge and slides whole: the object’s height and velocity, each pad’s force, travel and stuck fraction, and whether the grip slips.
    Validation & operating boundsCompared with the trials not in the fit, S2, S3 and S12 whole and level 4 of S4 to S11: on the 12 trials on natural glass of three fingers at 0.74 to 2.67 N, the card’s friction within 22.2 percent median (target 10; a constant force 31.5, each finger’s own coefficient 8.8) and its plate travel to full slip within 38.1 percent median (target 18; a constant travel 33.8) […] Gap: the stuck-fraction law, the stick ratio as the safety margin to the power 2/3, is off the measured stick ratio at 1 mm by 0.389 RMS over 16,126 samples of incipient slip (target 0.10; the ratio equal to the margin, 0.334) […]
  • Fed-batch bioreactor mass and oxygen balanceCompared with measurementsolver culture_trichoderma_ambr250One fed-batch culture of the fungus Trichoderma sp. VTT D-221704 in an ambr 250 vessel at pH 4.0 and 35 °C, turning D-galacturonate into mucic acid: biomass, glucose, galacturonate, mucic acid, carbon dioxide made and oxygen taken up at the end of every segment of the caller’s feeding record, carbon and electrons closed at every segment end.
    Validation & operating boundsCompared with the 4 cultures not in the fit, fed about 10.6 and about 50 g/L glucose, RMS error against targets of one and a half times the spread between repeats: oxygen taken up within 0.0108 mol (target 0.0153), dry biomass to 170 h within 1.05 g/L (target 2.15), glucose within 0.51 g/L (target 0.85) […] Gap: outside the fitted feed glucose it makes mucic acid too fast, by 4.4 to 6.8 g/L on average, and galacturonate and mucic acid are 6 to 8 g/L off from about 60 h on.
  • Fed-batch bioreactor ATP maintenance kineticsCompared with measurementsolver culture_trichoderma_atpOne fed-batch culture of the fungus Trichoderma sp. VTT D-221704 in an ambr 250 vessel at 35 °C, turning D-galacturonate into mucic acid on the energy the glucose supplies, oxidised where glucose is plentiful and burnt to carbon dioxide as it runs short: biomass, glucose, galacturonate, mucic acid, carbon dioxide made, oxygen taken up and galacturonate burnt at the end of every segment of the caller’s feeding record, carbon and electrons closed.
    Validation & operating boundsCompared with the 4 cultures not in the fit, at pH 3.5 and 3.0, RMS error against the targets of culture_trichoderma_ambr250: galacturonate within 1.83 g/L (target 2.74), mucic acid within 4.19 g/L (target 4.51), oxygen taken up within 0.01396 mol (target 0.0153) […] Gap: at pH 3.0 the measured batch runs slower than the solver’s, 5.81 g/L of glucose left at 45 h against 0.01, and the measured dry weight at pH 3.5 and 3.0 climbs to 13.8 to 17.4 g/L by 165 h where the solver holds 8.1 to 8.6.

Analytical reference models

  • Aluminum 6061 cold-plate thermal nodeAnalytical reference modelenergy/thermalAn aluminum 6061 avionics cold plate, 250 x 125 x 7.8 mm, heat capacity 590.625 J/K and 2 K/W to its bath, under heater power and a bath temperature, stepped by the exact exponential map from -40 to 125 degrees Celsius, the industrial rating of the electronics it carries.
  • 48 V DC feeder bus and AWG 34 copper fuse linkAnalytical reference modelenergy/grid_nodeA 48 V DC-plant node, a 50 uH feeder into a 50 uF shunt that rings at 20 krad/s, with an AWG 34 copper fuse link 0.1601 mm across and 120 mm long that melts at 1357.77 K, between an upstream voltage and a load current. It holds an energy ledger of the feeder, the shunt and the copper’s heat.
  • 60 Hz synchronous generator swing equationAnalytical reference modelenergy/swingOne round-rotor synchronous machine on a 60 Hz bus, inertia constant 5 s, damping 0.05 pu, peak electrical power 1.04 pu and a phase-locked loop of 20 per second, under mechanical power, held in synchronism inside a rotor angle of plus or minus pi/2.
  • 12S 22 Ah lithium-ion pack voltage sag and cutoffAnalytical reference modelenergy/battery_sagA 12S lithium-ion pack of 22 Ah, 50.4 V full and 36.0 V empty, with a straight-line rest voltage and a 0.060 ohm resistance that doubles as it empties, under a terminal current. It holds a chemical-energy ledger, a 42.0 V warning, a 36.0 V cutoff and a 50.4 V charging limit.
  • Annealed Ti-6Al-4V three-strut lattice columnAnalytical reference modelmaterials/ti64_latticeA three-strut annealed Ti-6Al-4V lattice column, yield 880 MPa, modulus 113.8 GPa, under nodal force, torque and temperature to 1268.15 K.
  • Steel hydraulic line valve-closure water hammerAnalytical reference modelsolver water_hammer_oil_lineWater hammer in a 4.0 m steel hydraulic line (12 x 1.5 mm tube, 9 mm bore) of mineral oil (870 kg/m^3, 1.72 GPa) between a held supply and a valve that closes […]
  • High-pressure mineral-oil column compressibilityAnalytical reference modelmaterials/hydraulic_fluidA 0.50 m mineral-oil column in a 50 mm bore, bulk modulus 1.72 GPa and density 870 kg/m^3, charged at one atmosphere, under a commanded flow, from its vapour pressure of 10 Pa to 20.74 MPa absolute.
  • ISO 6358 pneumatic orifice and chamber transientAnalytical reference modelsolver orifice_air_chamberA rigid 100 cm^3 chamber of air charged or vented through a pneumatic valve in the ISO 6358-1:2013 form (sonic conductance 1.0e-8 m^3/(s Pa), critical pressure ratio 0.30, subsonic index 0.5), with heat exchanged with the wall at 293.15 K: pressure, temperature and mass flow over time, choked and su […]
  • Pneumatic line and terminal-volume acoustic resonanceAnalytical reference modelsolver pneumatic_hose_resonanceThe pneumatic resonance of a 2.0 m polyamide hose (6 x 4 mm) feeding a closed 20 cm^3 volume, air at 293.15 K about a mean pressure […]
  • Damped 10 Hz mechanical isolation mountAnalytical reference modelsignal/resonanceA 1 kg mass on a 10 Hz mount, damping ratio 0.05 and stroke 15.625 mm, under an imposed acceleration, up to the energy of a free ring of twice the stroke.
  • Nonlinear 80 Hz Duffing resonatorAnalytical reference modelsignal/tesseractAn 80 Hz drive-mode Duffing resonator, damping ratio 1/80, cubic stiffness 6e8 per square metre per square second and proof mass 1e-7 kg, under acceleration, an external rate and sensed velocity, up to an amplitude of 7.8125 mm.
  • Dyneema high-modulus tensile tendonAnalytical reference modelmaterials/cable_stretchA 1.20 m Dyneema tendon 1.50 mm in diameter, modulus 120 GPa, damping ratio 0.01 and ultimate stress 2800 MPa, 4948 N at 28 mm of elongation, under a commanded force, in tension up to the tension at which it snaps.

Hand it to your agent.

https://mcp.zerotrustphysics.com/mcp
Open to any agent.

Something to paste

Connect to https://mcp.zerotrustphysics.com/mcp and read what is there. Then tell me what it is, and why it might matter to me.

Give it this page too.

What it will find

Every model in the library with its full specification: what it computes, its operating range, what it was fitted on, how close it comes on data outside the fit, its largest gap, and the inputs it refuses by name.

For agents and engineers

Connect your agent.

Point any MCP client at this address to list the models and run them. No key needed.

https://mcp.zerotrustphysics.com/mcp

A first call: list_cards {}

No LLM judge · --network none · CPU-native Rust · SHA-384 proofs, identical on Linux x86-64, Linux arm64 and macOS arm64.

curl -s https://mcp.zerotrustphysics.com/mcp -H 'Content-Type: application/json' -H 'Accept: application/json, text/event-stream' -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"list_cards","arguments":{}}}'