A nuclear test reactor · Technical reference

SPERT III

A small test reactor at the National Reactor Testing Station in Idaho, built like a commercial pressurised-water reactor in everything but size, and run in the 1960s to find out what such a reactor does when its power suddenly surges. Its model follows every series of tests its report gives, from a cold start to full power.


Whose measurements these are

R. K. McCardell, D. I. Herborn and J. E. Houghtaling set down what the reactor did, and how sure they were of each number.

They wrote for the Atomic Energy Division of Phillips Petroleum Company, under contract to the U.S. Atomic Energy Commission, and their report of March 1969 gives seventy surges of power in three of its tables, cold and hot, with a standard deviation beside the values, and that care is what lets a model be compared with their work more than half a century later.

The authors
R. K. McCardell, D. I. Herborn and J. E. Houghtaling
Written for
Phillips Petroleum Company, Atomic Energy Division, under contract to the U.S. Atomic Energy Commission, Idaho Operations Office
The report
Reactivity Accident Test Results and Analyses for the SPERT III E-Core: A Small, Oxide-Fueled, Pressurized-Water Reactor. Report IDO-17281, March 1969.
Where it is published
The U.S. Department of Energy’s Office of Scientific and Technical Information: doi.org/10.2172/4792676
The report’s own thanks
The authors thank M. Ishikawa, G. A. Mortensen, R. K. Stitt and M. W. King, and J. P. Campbell, J. F. Scott and W. A. Eisenbarth of the Oxide Core Kinetics Group, and write that the programme took the efforts of many people.

What happened

Seventy surges of power, given to a reactor on purpose, fill three tables of its 1969 report.

Some tests began cold, with the reactor barely running. Others began hot, at 1500 psig with the water flowing: from a startup, from hot standby at about 1 megawatt, or from operating power at 19. Each time a rod was ejected, and the power climbed.

how high how soon how much energy the rod moves
One surge, drawn and not plotted. The power lies low, climbs to a peak and falls away. The report gives three things for each surge: how high the peak was, how soon it came, and how much energy was released on the way up, shown here in orange.

How do you learn what a power reactor does in an accident without having the accident? In the 1960s one answer was to build a small reactor that could take it, and to give it the surge on purpose.

The E-core of SPERT III held 1392 rods of uranium oxide. Its tests ran in five series: thirty from a cold start, fifteen hot at 260 °F, seventeen hot at 500 °F, five from hot standby and three from operating power. In each, the fuel warmed, the warming itself held the reaction back, and the surge turned over.

McCardell, Herborn and Houghtaling recorded how high each surge went, how much energy it released on the way to the peak, when the peak came, and how hot the cladding of the hottest rod became. This page is about a model of the reactor fitted on all seventy, and compared with each of them in turn.


What the model did

Fitted on all seventy tests and compared with each one left out, the model gives peak power within 6.8 percent at the median test.

The model computes the reactor’s power, the energy it releases, and the temperatures of the fuel, the cladding and the water, through the whole surge: six groups of delayed neutrons, the transient rod’s worth over its travel, heat conducted through six rings of an average rod, of the rod under the cladding thermocouple and of the peak rod, the feedback of the fuel and of the water, and convection to the flow. It keeps a ledger of neutrons and one of heat, and closes both at every step.

It is fitted on all seventy tests of the report: eleven numbers, eight constants of the model, with the weight of the water’s feedback held at one, and the start powers of the three startup series. To see how it does on a test it was not fitted on, each test was left out in turn and the eleven numbers fitted again on the other sixty-nine. At the median test, peak power came within 6.8 percent, energy to the peak within 8.6, time to the peak within 4.1 and the rise of the hottest cladding within 9.2. Peak power was within two of the report’s standard deviations on 67 of the 70 tests.

By series, left out of the fit, at the median: cold startup 5.0 percent on peak power, 500 °F 6.3, 260 °F 14.9 high, hot standby 12.7 low. The largest gap is the three tests from operating power, 19 megawatts: 11.5 percent low in peak power, 81.2 percent low in energy and 39.0 percent early at the median. It sits in the first 0.15 seconds: the report’s own figures put the reactivity in over 0.10 to 0.16 seconds, where the model’s rod takes 0.06 to 0.08.

The verifier serves one model for each real object, under that object’s first ID: for this reactor, energy/reactor_spert3. The model of the cold surges alone that came before it is no longer served; a request for an earlier model of SPERT III is refused by name and pointed here. A dataset of 233 sealed runs of this model over the seventy tests, every run with its proof, is on Hugging Face.

Comparedwith measurement

One square for each of the 70 tests. The three hollow ones are from operating power, the largest gap.

Where it stops

Compared from a cold start to operating power. Past that it keeps going and flags every step. It stops where the fuel would melt or the water boil.

Extrapolation rule: “Past what a model was compared with, it keeps going with the same equations and flags every step. It stops only at a physical limit, or where its equations, constants or tables no longer hold, and it names the reason.”

What it was compared on

  • Reactivity of 0.46 to 1.29 dollars inserted by ejecting the transient rod.
  • Inlet water at 53 to 513 °F (284.8 to 540.4 K), at 0.0853 and 10.44 MPa.
  • No flow up to 24 feet a second (7.32 m/s), and starting power from 4e-6 to 19 megawatts.
  • Four things about each surge: peak power, energy to the peak, time to the peak and the rise of the hottest cladding, against the report’s own standard deviations.

Past that, and what its own description says of itself

  • Any reactivity of zero or more, any inlet above 273.15 K and below boiling, and any pressure from 0.000611657 to 22.064 MPa, with the same equations; each step far from every tested condition is flagged FLAG_OUTSIDE_COMPARED.
  • A run ends where a ring of the peak rod reaches 3120 K, the melting point of uranium oxide (FuelMelting), or where the water in the core reaches saturation (WaterAtSaturation).
  • Asked for 4 dollars from a cold start in steps of 0.1 milliseconds, about three times the most it was compared on, it flags every step, peaks at 40,918 megawatts at 0.107 seconds and stops at 0.173 seconds, where a ring of the peak rod reaches 3120 K (FuelMelting).
  • It refuses a reactivity below zero (ReactivityNegative), a reactivity changed during a run (ReactivityChangedDuringRun), a start outside the model (StateOutsideCard) and a step above its ceiling (DtAboveCeiling).
  • It has no scram, no void feedback and no second burst.
  • The startup tests give no initial power: the fitted 8.0, 4.1 and 8.3 watts are effective values for the three series.
  • Fuel temperature was never measured: the cladding thermocouple is modelled as a hot rod at 1.433 times the peak-to-average power density.

For the reader who wants every number

Exact engine specification.

Exact six-part specification served by engine 0.15.3 for energy/reactor_spert3 (validation tier: compared with measurement). Time-stepping models are addressed as cards and steady or boundary-value models as solvers; Refuses lists the named physical or domain boundaries where execution halts.

What it computes

Reactivity-insertion transient of the SPERT III E-core test reactor, 1392 UO2 rods, from cold startup, hot startup at 260 and 500 degF, hot standby or operating power, by six-group point kinetics with the transient rod’s worth over its travel, radial conduction in six rings of the average, the clad thermocouple’s and the peak rod, Doppler and moderator feedback and convection to the water: power, energy released, the fuel, clad and water temperatures and the hot-spot clad temperature, with the neutron and heat ledgers closed at every step.

Range

Range: compared at 0.46 to 1.29 dollars, inlet 53 to 513 degF (284.8 to 540.4 K), 0.0853 and 10.44 MPa, no flow to 24 ft/s (7.32 m/s) and initial power 4e-6 to 19 MW; computes any reactivity of zero or more, any inlet above 273.15 K and below saturation and any pressure from 0.000611657 to 22.064 MPa with the same equations, each step far from every tested condition flagged FLAG_OUTSIDE_COMPARED.

Fitted on

Fitted on all 70 tests of IDO-17281 Tables III, V and VII, every test read when the structure was chosen: eleven numbers, eight constants of the card (the moderator weight held at one) and the start powers of the three startup series, run on to its minimum.

Compared with

Compared with each of the 70 tests left out of the fit in turn, refitted on the other 69 from a start that never saw it: at the median test peak power within 6.8 percent, energy to the peak within 8.6, time to the peak within 4.1 and hot-spot clad rise within 9.2; 67 of 70, 61 of 70, 39 of 66 and 60 of 69 tests within two of the report’s standard deviations.

Gap

Gap: from operating power, 19 MW, the 3 tests read 11.5 percent low in peak power, 81.2 low in energy and 39.0 early at the median, the reactivity going in over 0.10 to 0.16 s in Figs. D-68 to D-70 against the rod’s 0.06 to 0.08 s; hot standby peak power 12.7 percent low, 260 degF 14.9 high.

Refuses

Refuses a reactivity below zero (ReactivityNegative) or changed during a run (ReactivityChangedDuringRun), a start outside the card (StateOutsideCard) and a step whose pieces under the state’s own ceiling would be shorter than 1e-9 s (DtAboveStateCeiling); a run ends where a ring of the peak rod reaches 3120 K (FuelMelting) or the core water reaches saturation (WaterAtSaturation).

Hand this one to your agent.

https://mcp.zerotrustphysics.com/mcp
Open to any agent.

Something to paste

Connect to https://mcp.zerotrustphysics.com/mcp and read the model energy/reactor_spert3. Then tell me what it is, and why it might matter to me.

Give it this page too.

What it will find

This model’s spec sheet: what it computes, its range, what it was fitted on, what it was compared with and how close it came, its gap and what it refuses.


An environment for your own system.

Have a physical system of your own? We build a physics environment around it, with its tasks and its verifier, from your system’s operational data. Custom environments start at $20,000 for scoping and the first milestone.

Start a custom environment See all four offers

Write
team@zerotrustphysics.com

For agents and engineers

Connect your agent.

Point any MCP client at this address to list the models and run them. No key needed.

https://mcp.zerotrustphysics.com/mcp

A first call: list_cards {}

No LLM judge · --network none · CPU-native Rust · SHA-384 proofs, identical on Linux x86-64, Linux arm64 and macOS arm64.

curl -s https://mcp.zerotrustphysics.com/mcp -H 'Content-Type: application/json' -H 'Accept: application/json, text/event-stream' -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"list_cards","arguments":{}}}'