The power source on NASA’s Curiosity rover · Technical reference

Curiosity’s generator

The radioisotope generator that NASA’s Curiosity rover carried to Mars, which has powered it since the landing in August 2012 and fades a little every day.


Whose measurements these are

Christofer Whiting and David Woerner gathered the power history of every radioisotope generator the United States has flown in space, and gave it away.

Whiting is at the University of Dayton and Woerner at the Jet Propulsion Laboratory, and their dataset covers the generators flown by NASA and the U.S. Department of Defense through 2023, published with no restriction on its use. For Curiosity it holds one daily-average reading for every day from the landing to October 2023, with no day missing.

The authors
Christofer Whiting and David Woerner
Where they work
The University of Dayton and the Jet Propulsion Laboratory
The dataset
Historical RTG Performance Data - 2023 Update. Dryad, 2023. Released under CC0.
Where it is published
doi.org/10.5061/dryad.1zcrjdfw2
Where the telemetry came from
The 2023 edition records that it was obtained courtesy of E. Clarke and L. Rich of the Idaho National Laboratory, and S. Bux and S. Pinkowski of the Jet Propulsion Laboratory.
The citation the authors ask for
C.E. Whiting and D.F. Woerner, “Chapter 8: Lifetime Performance of Spaceborne RTGs,” The Technology of Discovery: Radioisotope Thermoelectric Generators and Thermoelectric Technologies for Space Exploration, D.F. Woerner, Ed., John Wiley & Sons, 2023. ISBN 9781119811367.

What happened

The nuclear battery on Curiosity fades a little every day.

It was giving about 115 watts when the rover landed, and its output has been recorded every day since.

the landing fitted on compared with the modelreads high 2012 2023
The fade, drawn and not plotted. Brown is the generator’s power, falling slowly from the landing. To the left of the dotted line are the days the model is fitted on. To the right its answer, the dashed line, runs a little high, and the red is the gap.

Curiosity’s electricity comes from the heat of a radioisotope fuel. The fuel decays and the materials inside the generator wear, so the power falls, slowly and without pause.

How fast does it fall? Anyone planning a mission that has to last for decades wants to know. The record Whiting and Woerner published answers with measurement: a reading for every day on Mars, more than eleven years of them.

It sits in one dataset beside the generators of Voyager and Cassini and the rest, some of them still working decades after launch. The whole history of the technology is there to learn from, in public.


What the model did

Fitted on its first 2,060 days, the model followed the last 1,279 days of the record, outside the fit, within 0.94 watts.

The model computes the generator’s daily-average electrical power, its thermal power and the fading of its converter, from the landing on, with the energy ledger closed at every step. Its three constants are fitted on mission days 0 to 2,060 of the published record; days 2,061 to 2,808 chose its structure.

It was compared with the 1,279 days 2,809 to 4,087, the end of the published record, outside both: within 0.008129 of the generator’s 115.4 watts, root mean square, about 0.94 watts (target 0.010). Its worst day is 2.60 watts high, on mission day 3,546.

Its gap is that it reads high and the gap grows: +0.0031, +0.0045 and +0.0096 of 115.4 watts over three successive years, and +0.0107 over the last 184 days. Over the final 365 days the mean is +0.010094, about 1.16 watts, against a target of 0.010. Later days are expected to read higher still.

The verifier also serves a second form of the same generator, energy/generator_mmrtg_seebeck, in which the fuel’s decay enters twice. It is fitted on all 4,088 published days and comes within 0.00319 of 115.4 watts across them, about 0.37 watts; on days 2,809 to 4,087, 0.00397. Past day 4,087 every step is its forecast, flagged FLAG_PAST_FITTING_SPAN and FLAG_PAST_RECORD.

Comparedwith measurement

Over 1,279 days, RMS0.94 W

The final 365 days, mean1.16 W

Each bar against a full width of 1.154 W, the target of 0.010 of 115.4 W. The red at the end of the second is how far past the target the mean lands: 0.011 W.

Where it stops

Compared to the last day of the published record. Past that it keeps going and flags every step. It stops before the landing, or some 2,060 years after it.

Extrapolation rule: “Past what a model was compared with, it keeps going with the same equations and flags every step. It stops only at a physical limit, or where its equations, constants or tables no longer hold, and it names the reason.”

What it was compared on

  • One generator, flight unit F1 on Curiosity, and its daily-average electrical output.
  • Mission days 2,809 to 4,087, the end of the published record.

Past that, and what its own description says of itself

  • From the landing to about 2,060 years after it, 6.502e10 seconds, with the same equations; each step past day 4,087 is flagged FLAG_PAST_RECORD.
  • It refuses a mission time before the landing (MissionTimeBeforeLanding) and one past 6.502e10 seconds, where the decay heat the fuel still holds falls under a millionth of the heat released to day 4,087 (DecayHeatBelowLedgerResolution).
  • It reads high, and the gap grows: over the final 365 days the mean is +0.010094 of 115.4 watts, against a target of 0.010.
  • Another structure comes within both targets on days 2,809 to 4,087; it was found with those days read, and the model keeps the structure chosen without them, every constant as compared.
  • The record holds no measurement of heat, only the electrical output.

For the reader who wants every number

Exact engine specification.

Exact six-part specification served by engine 0.15.3 for energy/generator_mmrtg_f1 (validation tier: compared with measurement). Time-stepping models are addressed as cards and steady or boundary-value models as solvers; Refuses lists the named physical or domain boundaries where execution halts.

What it computes

Daily-average electrical output of one radioisotope generator, flight unit F1 on the Curiosity rover, from landing on, with no load: electrical power, thermal power and converter fading, with the energy ledger closed at every step.

Range

Range: compared on mission days 2,809 to 4,087, the end of the published record; computes from landing to about 2,060 years after it, 6.502e10 s, with the same equations, each step past day 4,087 flagged FLAG_PAST_RECORD.

Fitted on

Fitted on mission days 0 to 2,060 of the published daily record: three constants; days 2,061 to 2,808 chose the structure.

Compared with

Compared with the 1,279 days 2,809 to 4,087, outside the fit and the choice of structure: within 0.008129 of 115.4 W RMS (about 0.94 W; target 0.010), worst day +0.02251 (2.60 W high, day 3,546).

Gap

Gap: it reads high and the gap grows, +0.0031, +0.0045 and +0.0096 of 115.4 W over three successive years and +0.0107 over the last 184 days; the mean over the final 365 days is +0.010094 (about 1.16 W; target 0.010), and later days are expected to read higher still.

Refuses

Refuses a mission time before landing (MissionTimeBeforeLanding) and past about 2,060 years after landing, 6.502e10 s, where the decay heat still held falls under 1e-6 of the heat released to day 4,087 (DecayHeatBelowLedgerResolution).

Hand this one to your agent.

https://mcp.zerotrustphysics.com/mcp
Open to any agent.

Something to paste

Connect to https://mcp.zerotrustphysics.com/mcp and read the model energy/generator_mmrtg_f1. Then tell me what it is, and why it might matter to me.

Give it this page too.

What it will find

This model’s spec sheet: what it computes, its range, what it was fitted on, what it was compared with and how close it came, its gap and what it refuses.


An environment for your own system.

Have a physical system of your own? We build a physics environment around it, with its tasks and its verifier, from your system’s operational data. Custom environments start at $20,000 for scoping and the first milestone.

Start a custom environment See all four offers

Write
team@zerotrustphysics.com

For agents and engineers

Connect your agent.

Point any MCP client at this address to list the models and run them. No key needed.

https://mcp.zerotrustphysics.com/mcp

A first call: list_cards {}

No LLM judge · --network none · CPU-native Rust · SHA-384 proofs, identical on Linux x86-64, Linux arm64 and macOS arm64.

curl -s https://mcp.zerotrustphysics.com/mcp -H 'Content-Type: application/json' -H 'Accept: application/json, text/event-stream' -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"list_cards","arguments":{}}}'